SPECIFICATIONS :
- Accuracy class : OIML R60 C3
- Output sensitivity (=FS) : .0 0.2mV/V
- Maximum capacity (Emax) : 10, 20, 30, 50, 100, 200, 300, 500Kg
- Maximum number of load cell intervals (Nlc) : 3000
- Ratio of minimum LC verification interval Y = Emax / Vmin : 10000 15000, 6000
- Combined error : 0.020%FS
- Minimum dead load : 0kg
- Safe overload : 150%of Emax
- Ultimate overload : 300%of Emax
- Zero balance : < 1.0%of FS
- Excitation, recommended voltage : 5 ~ 12V
- Excitation maximum : 18V
- Terminal resistance, input : 430 50
- Terminal resistance, output : 351 2
- Insulation impedance : 5000 M (at 50V DC)
- Temperature range, compensated : -10 ~ 40C
- Temperature range, operating : -35 ~ +65C
- Element material : Stainless steel
- Ingress protection (according to EN 60529) : IP68
- Recommended torque on fixation bolts : M8 (20-50kg):15, M8 ( 300kg ):25, M10:40Nm
- ATEX classification (optional) : II1G Ex ia II1C T4, II1D Ex ia D 20 T73C, II3G nL IICT4